text.skipToContent text.skipToNavigation
  • Trade Only
  • Merlin-Partnership.svg
    In partnership with Williams Medical
Calling 01685 843676

GlucoRx HCT Ketone Strips x10

IDD613001, 394-8734, T5753

GlucoRx HCT Meter

GlucoRx HCT Meter is specifically for Type 1 diabetics is a quality, unique multiparameter machine. It contains Haematocrit Correcton Technology whcih provides a complete health check by measuring blood glucose, ketone and haematocrit.

GlucoRx HCT Glucose test strips use advanced enzyme technology with 2+ 2 (AC and DC) Bio Signal. The AC signal works to provide the haematocrit result and the DC calculates the glucose. The meter then corrects the glucose level according to the haematocrit value for enhanced accuracy in the self-management of diabetes.

Features

  • Results meet system accuracy requirements of ISO 15197:2015
  • Haematocrit Correction Technology for increased accuracy in self-management of blood glucose
  • 10 - 70% haematocrit range makes this suitable for use on newborns and pregnant ladies
  • Automatically identifies control solution testing
  • 1.0μL blood volume required and results in 5 seconds
  • Strip ejector, AST, AC/PC meal markers, day averages, 4 alarms, discreet testing and ketone warning
  • 1000 non-deletable result memory
  • Compatible with Diasend for easy viewing of result

 

METER FUNCTIONALITYGlucoRx HCT Meter
MeasuresBlood glucose, Haematocrit, Ketone
Test Strips & LancetsUses GlucoRx HCT Glucose Test Strips and GlucoRx HCT Ketone Test Strips. Also GlucoRx Lancets.
AccuracyExceeds latest ISO 15197:2013 system accuracy requirements
System Haematocrit10 – 70% (ketone strips); 0 – 70% (glucose strips)
Blood sample1.0µL for both Glucose & Ketone tests
Reaction time5 seconds for Glucose test, up to 10 seconds for Ketone test.
Measurement rangemmol/L fixed. 0.5 to 35 mmol/L for Glucose test, 0.1~8.0 mmol/L for Ketone test.
Measuring modesGen – any time of day, regardless of time since last meal. AC – No food intake for at least 8 hours. PC – 2 hours after a meal. Control solution test (QC) auto tagged.
Accomodates ASTOn fingertips and palm only when Ketone testing.
Strip ejection for safe disposalYes
Discreet testingBuzzer can be disabled
Ketone warning>15mmol/L
AlarmsFour
Day averages function7-, 14-, 21-, 28-, 60- & 90- day averages
SoftwarePC download facility; Eclipse Telehealth and Diasend compatibility pending.
Large, non-deletable memory1000 readings – suitable for Diabetic Drivers complying with DVLA guidelines
Dimensions96 (L) x 61 (W) x 26 (H) mm
Screen size50 x 35 mm
Product weight (including batteries)67.2g
Power (non-rechargeable)2x AAA
Other Special featuresBacklit screen, auto switch-off after 3 minutes without action and temperature warning.
Operating conditions10°C to 40°C (50°F to 104°F), below 85% R.H. (non-condensing)
Meter Storage/Transportation conditions-20°C to 60°C (-4°F to 140°F), below 95% R.H.
Strip Storage/Transportation conditions2°C to 32°C (35.6°F to 89.6°F) for glucose test strip and 2°C to 30°C, (35.6°F to 86°F) for β-ketone test strip, below 85% R.H.

 

See more See less
Specs
Product Data
Brand Glucorx
Reviews
Q&A
Downloads